Published 2009 | Version v1
Miscellaneous

Quantitative simultaneous determination some phenolic compounds by orthogonal signal correction partial least squares in real samples

  • 1. Yasouj University (Iran, Islamic Republic of). Department of Chemistry

Description

Complete text of publication follows. Phenolic components belong to a class of chemicals polluting, easily absorbed by animals and humans through the skin and Mucous membranes (S. Canofeni, S. DiSario, J. Mela, R. Pilloton, Anal. Lett. 27 (1994) 1659-1669). A simple, rapid and reliable method for simultaneous determination of multi-component phenolic pollutants has been made. PLS modeling is a powerful multivariate statistical tool and can be performed with easily accessible statically software (D.M. Haaland, E.V. Thomas, Anal.Chem.60 (1988) 1193-1202). Pre-processing method scan be applied in such situations to enhance the relevant in formation to make resulting models simpler and easier to interpret. Wold et al (S. Wold, H. Antti, F. Lindgren, J. Ohman, Chemom. Intell. Lab. Syst. 44 (1998) 175-185) introduced orthogonal signal correction (OSC) as a pre-processing step that improves the calibration model by filtering strong structured (i.e. .systematic) variation in X that is not correlated to Y. We use orthogonal signal correction partial least squares (OSC-PLS) method and the data were processed. A mixture design for standards was used in the calibration step to build the orthogonal signal correction partial least squares model. The linear range varied between 0.94-75.20, 1.39-41.64 and 1.10-66.24 μg ml-1 of phenol (PH), 4-nitrophenol (4-NP) and hydroquinone (HQ), respectively. The cross validation method was used to select the number of factors. The principle component of PH, 4-NP and HQ with and without OSC were, 3, 3, 3 and 3, 4, .5, respectively. To check the accuracy of the proposed method a recovery study on real samples was carried out. The PRESS for PH, 4-NP and HQ with and without OSC were, 3.7608, 2.0331, 3.5863 and 4.8348, 2.4052, 3.9598, respectively The RMSEP for PH, 4-NP and HQ with and without OSC were, 0.7330, 0.5389, .0.7158 and 0.8311, 0.5862, .7521, respectively. The results show that proposed method was successfully applied to the simultaneous determination of PH, 4-NP and HQ in synthetic samples, waste water, river water and tap water. The authors are grateful to Yasouj University for their help and support.

Part of:
36. Colloquium Spectroscopicum Internationale

Additional details

Identifiers

Publishing Information

Publisher
Eoetvoes Lorand University
Imprint Place
Budapest (Hungary)
Imprint Title
36. Colloquium Spectroscopicum Internationale
Imprint Pagination
[373 p.]
Journal Page Range
p. 318
Report number
INIS-HU--015

Conference

Title
36. Colloquium Spectroscopicum Internationale
Dates
30 Aug - 3 Sep 2009
Place
Budapest (Hungary)

INIS

Country of Publication
Hungary
Country of Input or Organization
Hungary
INIS RN
42046281
Subject category
S54: ENVIRONMENTAL SCIENCES;
Resource subtype / Literary indicator
Conference, Non-conventional Literature
Descriptors DEI
CORRECTIONS; MUCOUS MEMBRANES; PHENOLS; RIVERS; WASTE WATER
Descriptors DEC
AROMATICS; HYDROGEN COMPOUNDS; HYDROXY COMPOUNDS; LIQUID WASTES; MEMBRANES; ORGANIC COMPOUNDS; OXYGEN COMPOUNDS; SURFACE WATERS; WASTES; WATER

Optional Information