Tritium monitoring system using a modified Kanne chamber for use in tritium contaminating environments
Description
A Kanne chamber has been redesigned to reduce its sensitivity to such contaminants as tritium water vapor and tritiated oil. The high voltage electrode has been replaced by a wire cylinder and the collection electrode has been reduced in diameter. The sensitivity to contamination of the chamber has been reduced by about a factor of 40. The design allows for decontamination of the chamber in place. The improved electronics used is also discussed
Availability note (English)
MF available from INIS under the Report Number; Available from NTIS., PC A02/MF A01.
Files
Additional details
Publishing Information
- Imprint Pagination
- 13 p.
- Report number
- LA-UR--80-1209
Conference
- Title
- Tritium technology in fission, fusion, and isotopic applications.
- Dates
- 29 Apr - 1 May 1980.
- Place
- Dayton, OH, USA.
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 11559820
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- CONTAMINATION; ELECTRODES; ELECTRONIC CIRCUITS; IONIZATION CHAMBERS; MONITORING; SENSITIVITY; TRITIUM
- Descriptors DEC
- BETA DECAY RADIOISOTOPES; BETA-MINUS DECAY RADIOISOTOPES; HYDROGEN ISOTOPES; ISOTOPES; LIGHT NUCLEI; MEASURING INSTRUMENTS; NUCLEI; ODD-EVEN NUCLEI; RADIATION DETECTORS; RADIOISOTOPES; YEARS LIVING RADIOISOTOPES
Optional Information
- Secondary number(s)
- CONF-800427--5.