Association between IVIM parameters and treatment response in locally advanced squamous cell cervical cancer treated by chemoradiotherapy
Creators
- 1. Department of Diagnostic Radiology, Queen Mary Hospital, The University of Hong Kong, Room 406, Block K, Queen Mary Hospital, Pok Fu Lam Road, Hong Kong (China)
- 2. Department of Obstetrics and Gynaecology, Queen Mary Hospital, The University of Hong Kong, Hong Kong (China)
Description
To examine the associations of intravoxel incoherent motion (IVIM) parameters with treatment response in cervical cancer following concurrent chemoradiotherapy (CCRT). Forty-five patients, median age of 58 years (range: 28-82), with pre-CCRT and post-CCRT MRI, were retrospectively analysed. The IVIM parameters pure diffusion coefficient (D) and perfusion fraction (f) were estimated using the full b-value distribution (BVD) as well as an optimised subsample BVD. Dice similarity coefficient (DSC) and intraclass correlation coefficient (ICC) were used to measure observer repeatability in tumour delineation at both time points. Treatment response was determined by the response evaluation criteria in solid tumour (RECIST) 1.1 between MRI examinations. Mann-Whitney U tests were used to test for significant differences in IVIM parameters between treatment response groups. Pre-CCRT tumour delineation repeatability was good (DSC = 0.81) while post-CCRT delineation repeatability was moderate (DSC = 0.67). Values of D and f had good repeatability at both time points (ICC > 0.80). Pre-CCRT f estimated using the full BVD and optimised subsample BVD were found to be significantly higher in patients with partial response compared to those with stable disease or disease progression (p = 0.01 and 95% CI = -0.02-0.00 for both cases). Pre-CCRT f was associated with treatment response in cervical cancer with good observer repeatability. Similar discriminative ability was also observed in estimated pre-CCRT f from an optimised subsample BVD.
Availability note (English)
Available from: http://dx.doi.org/10.1007/s00330-021-07817-wAdditional details
Identifiers
Publishing Information
- Journal Title
- European Radiology (Internet)
- Journal Volume
- 31
- Journal Issue
- 10
- Journal Page Range
- p. 7845-7854
- ISSN
- 1432-1084
- CODEN
- EURAE3
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- Germany
- INIS RN
- 53002619
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- CARCINOMAS; CHEMOTHERAPY; COMBINED THERAPY; COMPARATIVE EVALUATIONS; CORRELATIONS; DIFFUSION; IMAGE PROCESSING; NMR IMAGING; RADIOTHERAPY; RELAXATION TIME; UROGENITAL SYSTEM DISEASES; WEIGHTING FUNCTIONS
- Descriptors DEC
- DIAGNOSTIC TECHNIQUES; DISEASES; EVALUATION; FUNCTIONS; MEDICINE; NEOPLASMS; NUCLEAR MEDICINE; PROCESSING; RADIOLOGY; THERAPY