Published October 1, 2017
| Version v1
Journal article
Analytic model for ultrasound energy receivers and their optimal electric loads II: Experimental validation
Creators
- 1. Department of Micro-actuators, IMTEK-University of Freiburg, Georges-Koehler Alle 102-02, D-79110 Freiburg im Breisgau (Germany)
Description
In this paper, we verify the two optimal electric load concepts based on the zero reflection condition and on the power maximization approach for ultrasound energy receivers. We test a high loss 1–3 composite transducer, and find that the measurements agree very well with the predictions of the analytic model for plate transducers that we have developed previously. Additionally, we also confirm that the power maximization and zero reflection loads are very different when the losses in the receiver are high. Finally, we compare the optimal load predictions by the KLM and the analytic models with frequency dependent attenuation to evaluate the influence of the viscosity. (paper)
Availability note (English)
Available from http://dx.doi.org/10.1088/1361-665X/aa86f6Additional details
Identifiers
Publishing Information
- Journal Title
- Smart Materials and Structures (Print)
- Journal Volume
- 26
- Journal Issue
- 10
- Journal Page Range
- [10 p.]
- ISSN
- 0964-1726
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 50034636
- Subject category
- S42: ENGINEERING;
- Descriptors DEI
- ATTENUATION; COMPARATIVE EVALUATIONS; FORECASTING; FREQUENCY DEPENDENCE; LOSSES; PLATES; REFLECTION; TRANSDUCERS; VALIDATION; VISCOSITY
- Descriptors DEC
- EVALUATION; TESTING