Published January 2004 | Version v1
Report

Pre-test calculation for PACTEL Test 3.2 with ATHLET code. 7.4 % cold leg break with primary bleed and feed. Rev. 0

Description

The PACTEL test facility is a volume-scaled model (1:305) of the Loviisa NPP. The calculation was performed with the help of the thermal-hydraulic code ATHLET Mod 1.2 Cycle D. As for the ECCS, the accumulators and LPIS were available in the test, which reproduced test 2.1 except that secondary bleed was not used

Availability note (English)

Available (also in the electronic format as a PDF reproduction) from Nuclear Research Institute Rez, 250 68 Rez, Czech Republic; e-mail contact: ret@nri.cz, ric@nri.cz

Additional details

Publishing Information

Imprint Pagination
30 p.
Report number
UJV--12033-T

Optional Information

Notes
4 tabs., 24 figs., 7 refs.