A Study on the Neutron in Radiation Treatment System and Related Facility
- 1. Dept. of Radiation Oncology, Asan Mdical Center, Seoul (Korea, Republic of)
- 2. Dept. of Radiology Science, College of Health Sciences, Korea University, Seoul (Korea, Republic of)
Description
It is known that the neutron is generally generated from the photon, its energy is larger than 10 MV. The neutron is leaked in the container inspection system installed at the customs though its energy is below 9 MV. It is needed that the special effect of the neutrons released from radiation treatment machine, linac, installed in the medical canter. The medical linear accelerator(Clinac 1800, varian, USA) was used in the experiment. Measuring neutron was used bubble detector(Bubble detector, BDPND type, BTI, Canada) which was created bubble by neutron. The bubble detector is located on the medical linear accelerator outskirt in three different distance, 30, 50, 120 cm and upper, lower four point from the iso-center. In addition, for effect on protect material we have measured eight points which are 50 cm distance from iso-center. The SAD(source-axis-distance), distance from photon source to iso-center, is adjusted to 100 cm and the field size is adjusted to 15 x 15 cm2. Irradiate 20 MU and calculate the dose rate in mrem/MU by measuring the number of bubble. The neutron is more detected at 5 position in 30, 50 cm, 7 position in 120 cm and with wedge, and 2 position without mount. Though detection position is laid in the same distance in neutron measurement, the different value is shown in measuring results. Also, neutron dose is affected by the additional structure, the different value is obtained in each measurement positions. So, it is needed to measure and evaluate the neutron dose in the whole space considering the effect of the distance, angular distribution and additional structure.
Additional details
Publishing Information
- Journal Title
- Journal of the Korean Society for Radiotherapeutic Technology
- Journal Volume
- 17
- Journal Issue
- 2
- Series
- 4 refs, 4 figs
- Journal Page Range
- p. 141-145
- ISSN
- 1598-8449
INIS
- Country of Publication
- Korea, Republic of
- Country of Input or Organization
- Korea, Republic of
- INIS RN
- 43125149
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- BUBBLES; INSPECTION; LINEAR ACCELERATORS; NEUTRONS; RADIOTHERAPY
- Descriptors DEC
- ACCELERATORS; BARYONS; ELEMENTARY PARTICLES; FERMIONS; HADRONS; MEDICINE; NUCLEAR MEDICINE; NUCLEONS; RADIOLOGY; THERAPY