Published April 2017 | Version v1
Journal article

IDACstar: a MCNP application to perform realistic dose estimations from internal or external contamination of radiopharmaceuticals

  • 1. Medical Radiation Physics, Department of Translational Medicine, Malmoe, Lund University, Skaane University Hospital, SUS Malmoe, SE-205 02 Malmoe (Sweden)
  • 2. Center for Radiation Protection Knowledge, Oak Ridge National Laboratory, Oak Ridge, TN (United States)

Description

A Monte Carlo-based stand-alone program, IDACstar (Internal Dose Assessment by Computer), was developed, dedicated to perform radiation dose calculations using complex voxel simulations. To test the program, two irradiation situations were simulated, one hypothetical contamination case with 600 MBq of 99mTc and one extravasation case involving 370 MBq of 18F-FDG. The effective dose was estimated to be 0.042 mSv for the contamination case and 4.5 mSv for the extravasation case. IDACstar has demonstrated that dosimetry results from contamination or extravasation cases can be acquired with great ease. An effective tool for radiation protection applications is provided with IDACstar allowing physicists at nuclear medicine departments to easily quantify the radiation risk of stochastic effects when a radiation accident has occurred. (authors)

Availability note (English)

Available from doi: http://dx.doi.org/10.1093/rpd/ncw221

Additional details

Identifiers

Publishing Information

Journal Title
Radiation Protection Dosimetry
Journal Volume
174
Journal Issue
3
Journal Page Range
p. 406-411
ISSN
0144-8420

Optional Information

Notes
20 refs.