Published November 1992 | Version v1
Report Open

Design improvements for the SSC CCL

  • 1. Superconducting Super Collider Lab., Dallas, TX (United States)

Description

This paper describes the beam-dynamics changes in the SSC Coupled Cavity Linac (CCL). In the previous design transverse emittance growth was 50%. This growth was due to the r-z coupling caused by rf defocusing. In the new design the r-z coupling is reduced by decreasing the beam size in the transverse and longitudinal direction. Beam size is reduced by (1) providing more transverse focusing, (2) removing the super-periodicity in the longitudinal plane and (3) reducing the number of cells per tank. The new design has only about 10% transverse emittance growth and uses one less klystron. (Author) 3 refs., 3 tabs., 4 figs

Files

28053569.pdf

Files (130.3 kB)

Name Size Download all
md5:7b67ba467430d86466f47bd4280f8d1c
130.3 kB Preview Download
Part of:
Proceedings of the 1992 linear accelerator conference

Additional details

Publishing Information

Imprint Title
Proceedings of the 1992 linear accelerator conference
Imprint Pagination
949 p.
Journal Page Range
p. 202-204.
Report number
AECL--10728(Vol.1,2)

Conference

Title
1992 Linear Accelerator Conference.
Dates
24-28 Aug 1992.
Place
Ottawa, ON (Canada).

INIS

Country of Publication
Canada
Country of Input or Organization
Canada
INIS RN
28053569
Subject category
S43: PARTICLE ACCELERATORS;
Resource subtype / Literary indicator
Conference
Descriptors DEI
BEAM EMITTANCE; FOCUSING; LINEAR ACCELERATORS; SPECIFICATIONS; SUPERCONDUCTING SUPER COLLIDER
Descriptors DEC
ACCELERATORS; CYCLIC ACCELERATORS; STORAGE RINGS; SYNCHROTRONS

Optional Information

Contract/Grant/Project number
Contract DE-AC02-89ER40486