The boron dilution event of PWR and measures of prevention and improvement

  • 1. Nuclear Safety Center, SEPA, Beijing (China)

Description

The boron dilution event can occur in all operation conditions of NPPs, and its one of the accidents assaulting to safety. The paper describes causes, consequences, prevention measures during design and improvement measures of the boron dilution event for PWR. (authors)