Investigation of periodic acceleration tube discharges with a capacitive pickup array
Description
Several diagnostic techniques are described, which were used to determine the cause of periodic tube discharges and consequent fast terminal voltage drops in an FN tandom accelerator which were observed to occur at high beam intensities for the voltage range 7 to 9 MV. Terminal voltage drops were first monitored with a generating voltmeter (GVM). As a result of this study it was decided to install an array of four capacitive pickups (mushrooms) along the length of the pressure vessel. Information obtained from these pickups and analysis of beam fluctuation data permitted the source of the difficulty to be identified as a high transmission grid installed at the entrance to acceleration tube 1
Availability note (English)
MF available from INIS under the Report Number; Available from NTIS., PC A02/MF A01.Files
12625092.pdf
Files
(245.5 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:1efe3101369f9e3cbea440f20f190972
|
245.5 kB | Preview Download |
Additional details
Publishing Information
- Imprint Pagination
- 3 p.
- Report number
- DOE/ER/01388--488
Conference
- Title
- 3. international conference on electrostatic accelerator technology.
- Dates
- 13 - 16 Apr 1981.
- Place
- Oak Ridge, TN, USA.
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 12625092
- Subject category
- S43: PARTICLE ACCELERATORS;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- BEAM TRANSPORT; BREAKDOWN; DIAGNOSTIC TECHNIQUES; ELECTRIC DISCHARGES; GRIDS; SECONDARY EMISSION; TANDEM ELECTROSTATIC ACCELERAT; VAN DE GRAAFF ACCELERATORS
- Descriptors DEC
- ACCELERATORS; ELECTRODES; ELECTROSTATIC ACCELERATORS; EMISSION
Optional Information
- Secondary number(s)
- CONF-810468--4.