Published March 2006 | Version v1
Report

Vibration measurements in a RHIC quadrupole at cryogenic temperatures

  • 1. Brookhaven National Laboratory, Upton, NY (United States)

Description

One of the concerns in using compact superconducting magnets in the final focus region of the ILC is the influence of the cryogen flow on the vibration characteristics. As a first step towards characterizing such motion at nanometer levels, a project was undertaken at BNL to measure the vibrations in a spare RHIC quadrupole under cryogenic conditions. Given the constraints of cryogenic operation, and limited space available, it was decided to use a dual head laser Doppler vibrometer for this work. The performance of the laser vibrometer was tested in a series of room temperature tests and compared with results from Mark L4 geophones. The laser system was then used to measure the vibration of the cold mass of the quadrupole with respect to the outside warm enclosure. These measurements were carried out both with and without the flow of cold helium through the magnet. The results indicate only a minor increase in motion in the horizontal direction (where the cold mass is relatively free to move). (author)

Part of:
Proceedings of NANOBEAM2005, 36th ICFA advanced beam dynamics workshop

Additional details

Publishing Information

Imprint Title
Proceedings of NANOBEAM2005, 36th ICFA advanced beam dynamics workshop
Imprint Pagination
480 p.
Journal Page Range
p. 319-324
Report number
KEK-PROC--2005-20

Conference

Title
36. ICFA advanced beam dynamics workshop
Acronym
NANOBEAM2005
Dates
17-21 Oct 2005
Place
Kyoto (Japan)

Optional Information

Notes
4 refs., 15 figs.