Published April 1997 | Version v1
Report Restricted

Application of break preclusion concept in German nuclear power plants

  • 1. Energie-Versorgung Schwaben AG, Stuttgart (Germany)
  • 2. Bayernwerk AG, Muenchen (Germany)
  • 3. PraussenElektra AG, Hannover (Germany)

Description

The break preclusion concept is based on open-quotes KTA rulesclose quotes, open-quotes RSK guidelinesclose quotes and open-quotes Rahmenspeziflkation Basissicherheitclose quotes. These fundamental rules containing for example requirements on material, design, calculation, manufacturing and testing procedures are explained and the technical realisation is shown by means of examples. The proof of the quality of these piping systems can be executed by means of fracture mechanics calculations by showing that in every case the leakage monitoring system already detect cracks which are clearly smaller than the critical crack. Thus the leak before break behavior and the break preclusion concept is implicitly affirmed. In order to further diminish conservativities in the fracture mechanics procedures, specific research projects are executed which are explained in this contribution

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Publishing Information

Imprint Title
Proceedings of the seminar on leak before break in reactor piping and vessels
Imprint Pagination
773 p.
Journal Page Range
p. 149.
Report number
NUREG/CP--0155

Conference

Title
Seminar on leak before break in reactor piping and vessels.
Dates
9-11 Oct 1995.
Place
Lyon (France).

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
28076022
Subject category
S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
Resource subtype / Literary indicator
Conference
Descriptors DEI
FRACTURE MECHANICS; LEAKS; PIPES; PWR TYPE REACTORS; SAFETY ANALYSIS
Descriptors DEC
ENRICHED URANIUM REACTORS; MECHANICS; POWER REACTORS; REACTORS; THERMAL REACTORS; WATER COOLED REACTORS; WATER MODERATED REACTORS

Optional Information

Secondary number(s)
CONF-9510432--.