Published February 1, 1997 | Version v1
Journal article

Automated planning target volume generation: an evaluation pitting a computer-based tool against human experts

Description

Purpose: Software tools are seeing increased use in three-dimensional treatment planning. However, the development of these tools frequently omits careful evaluation before placing them in clinical use. This study demonstrates the application of a rigorous evaluation methodology using blinded peer review to an automated software tool that produces ICRU-50 planning target volumes (PTVs). Methods and Materials: Seven physicians from three different institutions involved in three-dimensional treatment planning participated in the evaluation. Four physicians drew partial PTVs on nine test cases, consisting of four nasopharynx and five lung primaries. Using the same information provided to the human experts, the computer tool generated PTVs for comparison. The remaining three physicians, designated evaluators, individually reviewed the PTVs for acceptability. To exclude bias, the evaluators were blinded to the source (human or computer) of the PTVs they reviewed. Their scorings of the PTVs were statistically examined to determine if the computer tool performed as well as the human experts. Results: The computer tool was as successful as the human experts in generating PTVs. Failures were primarily attributable to insufficient margins around the clinical target volume and to encroachment upon critical structures. In a qualitative analysis, the human and computer experts displayed similar types and distributions of errors. Conclusions: Rigorous evaluation of computer-based radiotherapy tools requires comparison to current practice and can reveal areas for improvement before the tool enters clinical practice

Additional details

Identifiers

PII
S0360301696005627;

Publishing Information

Journal Title
International Journal of Radiation Oncology, Biology and Physics
Journal Volume
37
Journal Issue
3
Journal Page Range
p. 697-704
ISSN
0360-3016
CODEN
IOBPD3

INIS

Country of Publication
United States
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
35011293
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
AUTOMATION; ERRORS; EXPERT SYSTEMS; HUMAN FACTORS; IRRADIATION PROCEDURES; RADIOTHERAPY; SPATIAL DOSE DISTRIBUTIONS
Descriptors DEC
MEDICINE; NUCLEAR MEDICINE; RADIATION DOSE DISTRIBUTIONS; RADIOLOGY; THERAPY