Power of isotopic fine structure for unambiguous determination of metabolite elemental compositions: In silico evaluation and metabolomic application
Creators
- 1. Graduate School of Bioresource and Bioenvironmental Sciences, Kyushu University, 6-10-1 Hakozaki, Higashi-ku, Fukuoka 812-8581 (Japan)
- 2. Innovation Center for Medical Redox Navigation, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582 (Japan)
- 3. Bruker Daltonics K.K., 3-9 Moriya-cho, Kanagawa-ku, Yokohama 221-0022 (Japan)
- 4. Research Institute of Instrumentation Frontier, National Institute of Advanced Industrial Science and Technology, 2-42 Aomi, Koutou-ku, Tokyo 135-0064 (Japan)
- 5. Faculty of Arts and Science, Kyushu University, 6-10-1 Hakozaki, Higashi-ku, Fukuoka 812-8581 (Japan)
Description
Graphical abstract: - Highlights: • We developed a method to determine elemental composition of metabolites. • The method was based on mass spectral data and empirical constraints. • In the validation study, the method succeeded for 70% of detected peaks. - Abstract: In mass spectrometry (MS)-based metabolomics studies, reference-free identification of metabolites is still a challenging issue. Previously, we demonstrated that the elemental composition (EC) of metabolites could be unambiguously determined using isotopic fine structure, observed by ultrahigh resolution MS, which provided the relative isotopic abundance (RIA) of 13C, 15N, 18O, and 34S. Herein, we evaluated the efficacy of the RIA for determining ECs based on the MS peaks of 20,258 known metabolites. The metabolites were simulated with a ≤25% error in the isotopic peak area to investigate how the error size effect affected the rate of unambiguous determination of the ECs. The simulation indicated that, in combination with reported constraint rules, the RIA led to unambiguous determination of the ECs for more than 90% of the tested metabolites. It was noteworthy that, in positive ion mode, the process could distinguish alkali metal-adduct ions ([M + Na]+ and [M + K]+). However, a significant degradation of the EC determination performance was observed when the method was applied to real metabolomic data (mouse liver extracts analyzed by infusion ESI), because of the influence of noise and bias on the RIA. To achieve ideal performance, as indicated in the simulation, we developed an additional method to compensate for bias on the measured ion intensities. The method improved the performance of the calculation, permitting determination of ECs for 72% of the observed peaks. The proposed method is considered a useful starting point for high-throughput identification of metabolites in metabolomic research
Availability note (English)
Available from http://dx.doi.org/10.1016/j.aca.2014.01.032Additional details
Identifiers
- DOI
- 10.1016/j.aca.2014.01.032;
- PII
- S0003-2670(14)00097-X;
Publishing Information
- Journal Title
- Analytica Chimica Acta
- Journal Volume
- 813
- Journal Page Range
- p. 70-76
- ISSN
- 0003-2670
- CODEN
- ACACAM
INIS
- Country of Publication
- Netherlands
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 46028882
- Subject category
- S37: INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL CHEMISTRY; S60: APPLIED LIFE SCIENCES;
- Descriptors DEI
- ALKALI METALS; CATIONS; EVALUATION; FINE STRUCTURE; FOURIER TRANSFORMATION; ION CYCLOTRON-RESONANCE; LIVER; MASS SPECTROSCOPY; METABOLITES; MICE; MOLECULAR WEIGHT; PEAKS; SIMULATION
- Descriptors DEC
- ANIMALS; BODY; CHARGED PARTICLES; CYCLOTRON RESONANCE; DIGESTIVE SYSTEM; ELEMENTS; GLANDS; INTEGRAL TRANSFORMATIONS; IONS; MAMMALS; METALS; ORGANS; RESONANCE; RODENTS; SPECTROSCOPY; TRANSFORMATIONS; VERTEBRATES
Optional Information
- Copyright
- Copyright (c) 2014 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.