Published 1987
| Version v1
Book
Development of an emergency procedure guideline for station blackout for the Combustion Engineering owners group
Creators
- 1. Northeast Nuclear Energy Co., Millstone Nuclear Power, Waterford, CT (USA)
- 2. Combustion Engineering, Inc., Windsor, CT (United States)
Description
A strategy for operator response to station blackout events has been developed. This strategy optimizes the control of RCS heat removal rate by indexing it to the RCS leak rate as indicated by changes in the RCS subcooled margin. Optimum reactor operator control of steam and feed flow rates is based on maintaining RCS subcooling in the range of 11.1 - 27.8 degrees C (20-50 degrees F)
Additional details
Publishing Information
- Publisher
- American Nuclear Society.
- Imprint Place
- La Grange Park, IL (USA)
- ISBN
- 0-89448-136-3
- Imprint Title
- Anticipated and abnormal transients in nuclear power plants
- Imprint Pagination
- vp.
- Journal Page Range
- p. IV-42-IV-46.
Conference
- Title
- Topical meeting on anticipated and abnormal transients in nuclear power plants.
- Dates
- 12-15 Apr 1987.
- Place
- Atlanta, GA (USA).
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 22077658
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- CE STANDARD REACTOR; EMERGENCY PLANS; FLUID FLOW; HEAT TRANSFER; MEDIUM TEMPERATURE; OPTIMIZATION; OUTAGES; OWNERSHIP; REACTOR CONTROL SYSTEMS; REACTOR OPERATORS; REGULATORY GUIDES; STEAM
- Descriptors DEC
- CONTROL SYSTEMS; DOCUMENT TYPES; ENERGY TRANSFER; ENRICHED URANIUM REACTORS; PERSONNEL; POWER REACTORS; PWR TYPE REACTORS; REACTORS; THERMAL REACTORS; WATER COOLED REACTORS; WATER MODERATED REACTORS
Optional Information
- Secondary number(s)
- CONF-870418--.