Published June 1999 | Version v1
Journal article

Measured free-electron laser microbunching using coherent transition radiation

Description

The microbunch distribution of an electron beam exiting a SASE free-electron laser has been measured using the emitted coherent transition radiation (CTR) produced from a thin aluminum foil placed at the end of the undulator. The wavelength of the coherent transition radiation is shown to be the same as the FEL wavelength, and thus a measure of the beam microbunch spacing. Also, the study of the CTR linewidth and angular acceptance of the radiation captured are shown to be derived from this coherent radiative process. Scattering effects on the forward emitted transition radiation from the electron beam traversing an aluminum foil are also considered

Additional details

Identifiers

PII
S0168900299001059;

Publishing Information

Journal Title
Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
Journal Volume
429
Journal Issue
1-3
Journal Page Range
p. 209-212
ISSN
0168-9002
CODEN
NIMAER

Optional Information

Copyright
Copyright (c) 1999 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.