Published December 1976 | Version v1
Journal article

Electron microprobe analysis of niobium-based superconducting materials

  • 1. Brookhaven National Lab., Upton, N.Y. (USA)

Description

The results of investigations to ascertain the accuracy of electron probe composition measurements in four superconducting materials when the standards used are pure elements are described. Agreement between calculated and nominal valves with the computer corrected microprobe valves (within 1-2% for Nb) justifies the use of elemental standards. (U.K.)

Additional details

Identifiers

Publishing Information

Journal Title
Journal of Materials Science
Journal Volume
11
Journal Issue
12
Series
J. Mater. Sci.
Journal Page Range
2338-2340
ISSN
0022-2461

Optional Information

Notes
Updated automatically by Metadata and Full-Text Enrichment Agent