Reactor core water level monitor system is an important system used in CPR1000 nuclear power plant for monitoring the water level of reactor core after LOCA accident. The level measured by this system is used directly in the accident operation procedure. The principle of the measurement and the component of the system were introduced. According to the startup work of the first project for CPR1000, the goal for the first startup of this system relying on domestic engineering team was achieved. (authors)

Additional details

Publishing Information

Journal Title
Atomic Energy Science and Technology
Journal Volume
47
Journal Issue
4
Journal Page Range
p. 634-636