Published April 2013
| Version v1
Journal article
Reactor core water level monitor system and startup for CPR1000 nuclear power plant
- 1. China Nuclear Power Engineering Co., Ltd., Shenzhen (China)
Description
Reactor core water level monitor system is an important system used in CPR1000 nuclear power plant for monitoring the water level of reactor core after LOCA accident. The level measured by this system is used directly in the accident operation procedure. The principle of the measurement and the component of the system were introduced. According to the startup work of the first project for CPR1000, the goal for the first startup of this system relying on domestic engineering team was achieved. (authors)
Additional details
Publishing Information
- Journal Title
- Atomic Energy Science and Technology
- Journal Volume
- 47
- Journal Issue
- 4
- Journal Page Range
- p. 634-636
- ISSN
- 1000-6931
INIS
- Country of Publication
- China
- Country of Input or Organization
- China
- INIS RN
- 46132043
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Descriptors DEI
- ENGINEERING; IN CORE INSTRUMENTS; LEVEL INDICATORS; LOSS OF COOLANT; MONITORING; NUCLEAR POWER PLANTS; OPERATION; PWR TYPE REACTORS; REACTOR CORES; WATER
- Descriptors DEC
- ACCIDENTS; ENRICHED URANIUM REACTORS; HYDROGEN COMPOUNDS; MEASURING INSTRUMENTS; NUCLEAR FACILITIES; OXYGEN COMPOUNDS; POWER PLANTS; POWER REACTORS; REACTOR ACCIDENTS; REACTOR COMPONENTS; REACTOR INSTRUMENTATION; REACTORS; THERMAL POWER PLANTS; THERMAL REACTORS; WATER COOLED REACTORS; WATER MODERATED REACTORS
Optional Information
- Notes
- 2 figs., 1 tabs., 1 refs.