Published 1989
| Version v1
Journal article
Photon absorbed dose distribution in human phantom
Description
Fast-operating program for calculation of absorbed dose distribution and their average values in human organs and tissues simulated using MIRO-5 antropomorphous heterogeneous phantoms under E≤1.5 MeV energy photon irradiation is developed. It takes 20-30s to calculate one variant using Es 1060 computer, and it is on an average by 100 times less, than for calculation by Monte Carlo method. Results of comparison with experimantal data and calculations using Monte Carlo technique are given
Additional details
Additional titles
- Original title (Russian)
- Распределение поглощенной дозы фотонов в фантоме человека
Publishing Information
- Journal Title
- Atomnaya Ehnergiya
- Journal Volume
- 67
- Journal Issue
- 6
- Series
- At. Ehnerg.
- Journal Page Range
- 396-399
- ISSN
- 0004-7163
- CODEN
- AENGA
INIS
- Country of Publication
- Russian Federation
- Country of Input or Organization
- USSR
- INIS RN
- 22055425
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY; S99: GENERAL AND MISCELLANEOUS;
- Descriptors DEI
- CRITICAL ORGANS; GAMMA RADIATION; KEV RANGE 100-1000; MAN; MEV RANGE 01-10; PHANTOMS; R CODES; SPATIAL DOSE DISTRIBUTIONS; TISSUE-EQUIVALENT MATERIALS; TISSUES
- Descriptors DEC
- ANIMALS; BODY; COMPUTER CODES; DISTRIBUTION; ELECTROMAGNETIC RADIATION; ENERGY RANGE; IONIZING RADIATIONS; KEV RANGE; MAMMALS; MATERIALS; MEV RANGE; MOCKUP; ORGANS; PRIMATES; RADIATION DOSE DISTRIBUTIONS; RADIATIONS; SPATIAL DISTRIBUTION; STRUCTURAL MODELS; VERTEBRATES