Published April 1989 | Version v1
Journal article

On the use of automatic pipets in volume calibration of accountability tanks

Creators

  • 1. Potomac, Maryland, U.S.A., MD (USA)

Description

The applicability of automatic pipets for dispensing known volumes of water in the volume calibration of accountability tanks of tens-of-liters capacity is demonstrated. Six pipet of capacity in the approximate range 495 to 716 milliliters were calibrated using gravimetric techniques. The relative standard deviation ranged from 0.0015% to 0.0074%. The pipets were used successfully in the volume calibration of accountability tanks of tens-of-liters capacity in the Savannah River Plant

Additional details

Publishing Information

Journal Title
JNMM
Journal Volume
17
Journal Issue
3
Series
JNMM.
Journal Page Range
32-33
ISSN
0893-6188
CODEN
JNMME

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
21003620
Subject category
S98: NUCLEAR DISARMAMENT, SAFEGUARDS AND PHYSICAL PROTECTION; S42: ENGINEERING;
Descriptors DEI
AUTOMATION; CALIBRATION; GRAVIMETRY; SAVANNAH RIVER PLANT; TANKS
Descriptors DEC
CONTAINERS; NATIONAL ORGANIZATIONS; US AEC; US DOE; US ERDA; US ORGANIZATIONS