Image quality and diagnostic value of ultra low-voltage, ultra low-contrast coronary CT angiography
Creators
- 1. Department of Cardiovascular Radiology, The First Affiliated Hospital of Dalian Medical University, Dalian (China)
- 2. Invasive Technology Department, Qingdao City Chengyang District People's Hospital (China)
- 3. Radiology Department, Xi'an No. 3 Hospital (China)
- 4. Department of Cardiology, The First Affiliated Hospital of Dalian Medical University, Dalian (China)
Description
To explore the image quality (IQ) and diagnostic value of 70 kVp turbo high-pitch coronary CT angiography (THP-CCTA) using automated tube voltage selection (ATVS) and 30 mL of low-concentration contrast agent. Patients who underwent 70 kVp THP-CCTA using ATVS with 30 mL of contrast agent (group A) were prospectively enrolled, and those who underwent conventional CCTA (100/120 kVp, prospective sequential mode with 65–75 mL of contrast agent) (group B) were retrospectively selected for study. IQ was assessed subjectively on a 5-point scale, and diagnostic value was assessed based on invasive coronary angiography as the gold standard. Heart rate (HR), HR fluctuation (HRF), body mass index (BMI), effective radiation dose (ED), and iodine uptake (IU) were recorded. A total of 796 patients (398/398 in groups A/B) were included. Between-group differences in age, gender, BMI, HR, HRF, and IQ values were not significant. The ED/IU values were 0.3 ± 0.1 mSv/9.0 ± 0.0 g and 5.8 ± 1.8 mSv/22.9 ± 1.0 g in groups A and B, respectively (p < 0.01). The sensitivity, specificity, positive and negative predictive values, and accuracy of THP-CCTA for the diagnosis of ≥ 50% stenosis were 94.8%, 97.5%, 92.0%, 98.4%, and 96.9% respectively. The mean HR and coronary calcium score were independent predictors of diagnostic image quality, and the best cutoff values were 71.5 bpm and 444.1 respectively. This third-generation dual-source CT imaging modality, a 70-kVp THP-CCTA system using ATVS with 30 mL of low-concentration contrast agent, produces high-quality images with high diagnostic accuracy for significant stenosis, with ultra low ED and IU. This technique was most promising in individuals with an HR < 71.5 bpm and coronary calcium score < 444.1.
Availability note (English)
Available from: http://dx.doi.org/10.1007/s00330-019-06111-0Additional details
Identifiers
Publishing Information
- Journal Title
- European Radiology
- Journal Volume
- 29
- Journal Issue
- 7
- Journal Page Range
- p. 3678-3685
- ISSN
- 0938-7994
- CODEN
- EURAE3
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- Germany
- INIS RN
- 51001570
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- ACCURACY; BIOMEDICAL RADIOGRAPHY; CALCIUM; CARDIOVASCULAR DISEASES; COMPUTERIZED TOMOGRAPHY; CONCENTRATION RATIO; CONTRAST MEDIA; CORONARIES; DIAGNOSIS; EFFECTIVE RADIATION DOSES; ELECTRIC POTENTIAL; IMAGE SCANNERS; IODINE; SENSITIVITY; SPECIFICITY; UPTAKE; X-RAY TUBES
- Descriptors DEC
- ALKALINE EARTH METALS; ARTERIES; BLOOD VESSELS; BODY; CARDIOVASCULAR SYSTEM; DIAGNOSTIC TECHNIQUES; DIMENSIONLESS NUMBERS; DISEASES; DOSES; ELECTRON TUBES; ELEMENTS; EQUIPMENT; HALOGENS; MEDICINE; METALS; NONMETALS; NUCLEAR MEDICINE; ORGANS; RADIATION DOSES; RADIOLOGY; TOMOGRAPHY; X-RAY EQUIPMENT