Published June 2010 | Version v1
Journal article

Assessment of left ventricular function with single breath-hold highly accelerated cine MRI combined with guide-point modeling

  • 1. Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen (Germany)
  • 2. Siemens AG Healthcare Sector, MED MR PLM AW Cardiology, Erlangen (Germany)
  • 3. Siemens AG Healthcare Sector, Cardiovascular MR Research and Development, Chicago (United States)

Description

Purpose: To prospectively assess the performance of highly accelerated cine MRI in multi-orientations combined with a new guide-point modeling post-processing technique (GPM approach) for assessment of left ventricular (LV) function compared to the standard summation of slices method based on a stack of short axis views (SoS approach). Materials and methods: 33 consecutive patients were examined on a 1.5 T scanner with a standard steady state free precession (SSFP) sequence (TR, 3.0 ms; TE, 1.5 m; flip angle (FA), 60o; acceleration factor (AF), 2) analyzed with the SoS method and a highly accelerated, single breath-hold temporal parallel acquisition SSFP sequence (TR, 4.6 ms; TE, 1.1 ms; AF, 3) post-processed with the GPM method. LV function values were measured by two independent readers with different experience in cardiac MRI and compared by using the paired t-test and F-test. Inter- and intraobserver agreements were calculated using Bland-Altman-Plots. Results: Mean acquisition and post-processing time was significantly shorter with the GPM approach (15 s/3 min versus 360 s/6 min). For all LV function parameters interobserver agreement between the experienced and non-experienced reader was significantly improved when the GPM approach was used. However, end-diastolic and end-systolic volumes were larger for the GPM technique when compared to the SoS method (P < 0.001), whereas ejection fraction estimation yielded equivalent results (P > 0.121). In both readers and for all parameters variances did not differ significantly (P ≥ 0.409) and the two approaches showed an excellent linear correlation (r > 0.951). Conclusion: Due to its accurate, fast and reproducible assessment of LV function parameters highly accelerated MRI combined with the GPM technique may become the technique of first choice for assessment of LV function in clinical routine.

Availability note (English)

Available from http://dx.doi.org/10.1016/j.ejrad.2009.03.028

Additional details

Identifiers

DOI
10.1016/j.ejrad.2009.03.028;
PII
S0720-048X(09)00142-9;

Publishing Information

Journal Title
European Journal of Radiology
Journal Volume
74
Journal Issue
3
Journal Page Range
p. 492-499
ISSN
0720-048X
CODEN
EJRADR

INIS

Country of Publication
Netherlands
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
42034850
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
BREATH; HEART; NMR IMAGING; PERFORMANCE; SIMULATION; STEADY-STATE CONDITIONS
Descriptors DEC
BODY; CARDIOVASCULAR SYSTEM; DIAGNOSTIC TECHNIQUES; ORGANS

Optional Information

Copyright
Copyright (c) 2009 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.