Experimental determination of the radiation dose distribution in heterogeneous medium submitted to gamma and x-rays

Description

An experimental study of the perturbation caused by a cylindrical inhomogeneity on dose distribution in a water phantom, irradiated by high energy photons was performed, employing radiographic film as dosimeter. These materials were used to simulate the interface between bone and muscular tissue. (author)

Availability note (English)