Neutral beam power measurements inside the ASDEX torus
Description
Neutral beam power measurements inside the ASDEX torus are done with a retractable calorimeter which is only radiation cooled. The calorimeter plate made from Molybdenum is subdivided into nine segments whose increase in energy content due to a shot yields the absorbed beam power. Different models for the backward extrapolation of the measured temperature curves are examined for a series of low energy shots with the result that pure radiation cooling is a valid assumption. Furthermore, a temperature correction to the measured power is derived from these experiments. The evaluation of the shots onto this calorimeter is done by a computer program. The application of this program to a few full power shots shows that a neutral power up to 3.2 MW has been injected into the ASDEX vessel by the two injectors with an overall efficiency of up to 40%. Reionization losses due to the ASDEX stray field are less than 10%; they do not show any dependence upon the pulse length for shots up to 200 ms. (orig.)