Published 1999 | Version v1
Journal article

Direct contact boiling of initially subcooled R 114 into water

  • 1. ENEA, Casaccia (Italy). Institute of Thermal-Fluid Dynamics
  • 2. Rome Univ. La Sapienza (Italy)

Description

An experimental research on direct contact boiling of an initially subcooled liquid R 114 (dispersed phases) into water (continuous phase) has been carried out whit the aim for verifying the effect of water superheating (difference between water temperature and R 114 saturation temperature at system pressure) and the effect of freon subcooling on the heat transfer process, as well as to check a previous model developed for saturation tests: the subcooling is considered in a acceptable way from this model, because there is no clear dependence of coefficients and b from ΔTsub. The trend of a and b confirm the conclusion reached in the 'saturation' tests, from which the evaporation was aided above all by the great turbulence included by higher inlet velocities, while the non-vaporized freon, falling down, reduces itself as the water superheating ΔTs increases, annealing itself almost for ΔTs equal to 18-20 K

Additional details

Publishing Information

Journal Title
Heat and Technology
Journal Volume
17
Journal Issue
1
Journal Page Range
p. 75-84
ISSN
0392-8764
CODEN
HETEEE

INIS

Country of Publication
Italy
Country of Input or Organization
Italy
INIS RN
31008924
Subject category
S42: ENGINEERING;
Descriptors DEI
FREONS; HEAT TRANSFER; SATURATION; SUBCOOLED BOILING; SUPERHEATING; TURBULENCE
Descriptors DEC
BOILING; ENERGY TRANSFER; HEATING; ORGANIC COMPOUNDS; ORGANIC HALOGEN COMPOUNDS; PHASE TRANSFORMATIONS