An experimental research on direct contact boiling of an initially subcooled liquid R 114 (dispersed phases) into water (continuous phase) has been carried out whit the aim for verifying the effect of water superheating (difference between water temperature and R 114 saturation temperature at system pressure) and the effect of freon subcooling on the heat transfer process, as well as to check a previous model developed for saturation tests: the subcooling is considered in a acceptable way from this model, because there is no clear dependence of coefficients and b from ΔTsub. The trend of a and b confirm the conclusion reached in the 'saturation' tests, from which the evaporation was aided above all by the great turbulence included by higher inlet velocities, while the non-vaporized freon, falling down, reduces itself as the water superheating ΔTs increases, annealing itself almost for ΔTs equal to 18-20 K
Additional details
Publishing Information
- Journal Title
- Heat and Technology
- Journal Volume
- 17
- Journal Issue
- 1
- Journal Page Range
- p. 75-84
- ISSN
- 0392-8764
- CODEN
- HETEEE
INIS
- Country of Publication
- Italy
- Country of Input or Organization
- Italy
- INIS RN
- 31008924
- Subject category
- S42: ENGINEERING;
- Descriptors DEI
- FREONS; HEAT TRANSFER; SATURATION; SUBCOOLED BOILING; SUPERHEATING; TURBULENCE
- Descriptors DEC
- BOILING; ENERGY TRANSFER; HEATING; ORGANIC COMPOUNDS; ORGANIC HALOGEN COMPOUNDS; PHASE TRANSFORMATIONS