Published December 16, 1974 | Version v1
Report Restricted

Final task report on Fort St. Vrain temperature scanner system

Description

A Fort St. Vrain temperature scanner system was designed. Its primary use is to display in graphic format the thermal distribution of the helium, the feedwater, and the steam temperatures on the 12 steam generators during rise-to-power testing at the Fort St. Vrain High-Temperature Gas-Cooled Reactor. The graphic information allows an operator to immediately access hot spots, thermal imbalance, and any thermal information that indicates impending trouble. The system, including the software written for it, is described. (auth)

Availability note (English)

MF available from INIS under the Report Number.

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Publishing Information

Imprint Pagination
223 p.
Report number
GA-A--13229