Published 1983
| Version v1
Report
Open
Results of quality control studies of technetium 99m labelled radiopharmaceuticals prepared from kits (1980-81)
Description
This report summarized the results of quality control studies of Tc 99m labelled human serum albumin, macroaggregated albumin, bone imaging and reticuloendothelial system imaging radiopharmaceuticals prepared from commercially available kits. It includes all analyses performed from January 1980 to December 1981 by the radiopharmaceutical quality control section of the Radiation Protection Bureau. These results were obtained by the application of various in vitro and animal (mouse) biodistribution studies
Availability note (English)
MF available from INIS under the Report Number.Files
16030469.pdf
Files
(615.9 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:56c34c5e747512b9f6272ddf808d720f
|
615.9 kB | Preview Download |
Additional details
Publishing Information
- Imprint Pagination
- 70 p.
- Report number
- EHD--83-100
INIS
- Country of Publication
- Canada
- Country of Input or Organization
- Canada
- INIS RN
- 16030469
- Subject category
- S63: RADIATION, THERMAL, AND OTHER ENVIRONMENTAL POLLUTANT EFFECTS ON LIVING ORGANISMS AND BIOLOGICAL MATERIALS;
- Descriptors DEI
- QUALITY CONTROL; RADIOPHARMACEUTICALS; TECHNETIUM 99
- Descriptors DEC
- BETA DECAY RADIOISOTOPES; BETA-MINUS DECAY RADIOISOTOPES; CONTROL; DRUGS; HOURS LIVING RADIOISOTOPES; INTERMEDIATE MASS NUCLEI; ISOMERIC TRANSITION ISOTOPES; ISOTOPES; LABELLED COMPOUNDS; MATERIALS; NUCLEI; ODD-EVEN NUCLEI; RADIOACTIVE MATERIALS; RADIOISOTOPES; TECHNETIUM ISOTOPES; YEARS LIVING RADIOISOTOPES
Optional Information
- Notes
- French version included.