Effect of vent pipe configurations on suppression pool hydrodynamics

  • 1. Reactor Safety Division, Bhabha Atomic Research Centre, Mumbai (India)

Description

Water and Steam Interaction Facility (WASIF) phase-II is being setup at SRI, AERB, Kalpakkam for suppression pool hydrodynamics experiments for various vent pipes configurations. Pre-test analyses have been carried out to evaluate the flow rate, flow pattern and hydrodynamic pressure which will be useful for instrument selection and placing instruments at suitable places for vital information using CFD code. Total six vent pipe configurations (two downward flow exiting type and four side/lateral flow exiting type) were analysed and air instead of steam-air mixture was considered as domain fluid. The analysis finds that the downward exiting configurations are better suitable for suppression pool due to more residence time, less pressure drop and relatively less hydrodynamics forces. (author)

Files

53034760.pdf

Files (2.5 MB)

Name Size Download all
md5:d35497b23d4738054d795c16dcfd1be4
2.5 MB Preview Download

Additional details

Publishing Information

Imprint Pagination
39 p.
Report number
BARC--2021/E/024

INIS

Country of Publication
India
Country of Input or Organization
India
INIS RN
53034760
Subject category
S30: DIRECT ENERGY CONVERSION;
Descriptors DEI
COMPUTERIZED SIMULATION; FLOW RATE; FLUID FLOW; HYDRODYNAMICS; VENTS
Descriptors DEC
FLUID MECHANICS; MECHANICS; SIMULATION

Optional Information

Notes
15 refs., 33 figs., 1 tab.