Dynamic modeling, validation and analysis of direct air-cooling condenser with integration to the coal-fired power plant for flexible operation
Creators
- 1. Key Laboratory of Energy Thermal Conversion and Control of Ministry of Education, School of Energy and Environment, Southeast University, Nanjing 210096 (China)
- 2. Department of Electrical and Computer Engineering, Baylor University, Waco, TX 76798 (United States)
Description
Highlights: • A nonlinear plant-wide transient model for a 660 MWe CFPP integrated with DACC. • Multi-section DACC model encompassing the crosswind and ambient temperature disturbances. • Hybrid modeling combining first principles with information in operating data. • Sufficient validations under various operating conditions against the field data. • A novel DACC control strategy proposed for flexible operation of the DACC-CFPP. Coal-fired power plants with direct air-cooling condensers (DACC-CFPPs) have been widely used in areas rich in coal but short of water since they can significantly reduce water consumption. Despite its water-saving advantages, direct air-cooling condensers have inherent defects such as environmental and load sensitivity, higher costs and poor cooling performance, which deteriorate the economics and flexibility of the integrated system. For safe, efficient and flexible operation, this paper presents the development of a direct air-cooling condenser dynamic model integrated with a 600 MWe coal-fired power plant to study the interactions between heat and power within the entire DACC-CFPP under various load and ambient conditions. The condenser is modeled in a one-dimensional multi-section manner to reflect the impacts of crosswind and ambient temperature disturbances. A detailed turbine-feedwater heater system model is also developed to link the direct air-cooling condenser and power plant together. Steady-state and dynamic validations under various operating conditions are conducted, which demonstrate the high fidelity of the developed model. Simulation studies are then carried out to investigate the dynamic interactions between boiler-turbine, condenser and environmental conditions. We find that manipulating the fan array speed controls the condenser pressure effectively in terms of environmental disturbance rejection and load ramping. Motivated by this finding, a novel variable condenser pressure operating mode is proposed to coordinate the direct air-cooling condenser and coal-fired power plant operation, which can significantly improve the load tracking performance of the integrated plant.
Availability note (English)
Available from http://dx.doi.org/10.1016/j.enconman.2021.114601Additional details
Identifiers
- DOI
- 10.1016/j.enconman.2021.114601;
- PII
- S0196890421007779;
Publishing Information
- Journal Title
- Energy Conversion and Management
- Journal Volume
- 245
- Journal Page Range
- vp.
- ISSN
- 0196-8904
- CODEN
- ECMADL
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 54031071
- Subject category
- S42: ENGINEERING;
- Descriptors DEI
- AMBIENT TEMPERATURE; COAL; COMPUTERIZED SIMULATION; HEAT; HEAT EXCHANGERS; NONLINEAR PROBLEMS; ONE-DIMENSIONAL CALCULATIONS; SENSITIVITY; STEADY-STATE CONDITIONS; TURBINES; VAPOR CONDENSERS
- Descriptors DEC
- CARBONACEOUS MATERIALS; ENERGY; ENERGY SOURCES; EQUIPMENT; FOSSIL FUELS; FUELS; MACHINERY; MATERIALS; SIMULATION; TURBOMACHINERY