Published January 10, 1993 | Version v1
Journal article

Solid state radioisotopic energy converter for space nuclear power

Creators

  • 1. IsoGen Radioisotopic Research Laboratory, 315 S. McLoughlin Blvd., Oregon City, Oregon 97045 (United States)

Description

Recent developments in materials technology now make it possible to fabricate nonthermal thin-film radioisotopic energy converters (REC) with a specific power of 24 W/kg and a 10 year working life at 5 to 10 watts. This creates applications never before possible, such as placing the power supply directly on integrated circuit chips. The efficiency of the REC is about 25% which is two to three times greater than the 6 to 8% capabilities of current thermoelectric systems. Radioisotopic energy converters have the potential to meet many future space power requirements for a wide variety of applications with less mass, better efficiency, and less total area than other power conversion options. These benefits result in significant dollar savings over the projected mission lifetime

Additional details

Publishing Information

Journal Title
AIP Conference Proceedings
Journal Volume
271
Journal Issue
1
Journal Page Range
p. 325-331.
ISSN
0094-243X
CODEN
APCPCS

Conference

Title
10. symposium on space nuclear power and propulsion.
Dates
10-14 Jan 1993.
Place
Albuquerque, NM (United States).

Optional Information

Secondary number(s)
CONF-930103--.