An adsorption method for BR-5 primary cover gas decontamination from radioactive xenon

Description

The importance of cover gas decontamination is discussed. An experimental gas decontamination system is used for the primary coolant circuit of the SBR-5 reactor. Results of decontamination using experimental systems are analysed

Files

9361006.pdf

Files (329.6 kB)

Name Size Download all
md5:50ce1831419365827991fc7040b3c7a5
329.6 kB Preview Download

System files (45.8 kB)

Name Size Download all

Additional details

Additional titles

Original title (Russian)
Адсорбционный метод очистки защитного газа первого контура реактора BR-5 от радиоактивного ксенона

Publishing Information

Imprint Title
Specialists' meeting on fission and corrosion product behaviour in primary circuits of LMFBR's, Dimitrovgrad, USSR, September 8-11, 1975. Summary report
Journal Page Range
p. 157-162.