Measurement error in pressure-decay leak testing

Description

The effect of measurement error in presssure-decay leak testing is considered, and examples are presented to demonstrate how it can be properly accomodated in analyzing data from such tests. Suggestions for more effective specification and conduct of leak tests are presented