Published April 1979
| Version v1
Report
Open
Measurement error in pressure-decay leak testing
Description
The effect of measurement error in presssure-decay leak testing is considered, and examples are presented to demonstrate how it can be properly accomodated in analyzing data from such tests. Suggestions for more effective specification and conduct of leak tests are presented
Availability note (English)
MF available from INIS under the Report Number; Available from NTIS., PC A02/MF A01.Files
10480387.pdf
Files
(303.8 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:d74a5d7a49d2ef64424ac034cea47a11
|
303.8 kB | Preview Download |
Additional details
Publishing Information
- Imprint Pagination
- 16 p.
- Report number
- ORNL/TM--6855
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 10480387
- Subject category
- S42: ENGINEERING;
- Descriptors DEI
- ERRORS; LEAK TESTING; MEASURING METHODS; PRESSURE VESSELS; VACUUM SYSTEMS
- Descriptors DEC
- CONTAINERS; TESTING