The use of energy windowing to discriminate SNM from NORM in radiation portal monitors
Creators
- 1. Pacific Northwest National Laboratory, MS P8-20, P.O. Box 999, Richland, WA 99352 (United States)
Description
Energy windowing is an algorithmic alarm method that can be applied to plastic scintillator-based radiation portal monitor (RPM) systems to improve operational sensitivity to certain threat sources while reducing the alarm rates from naturally occurring radioactive material. Various implementations of energy windowing have been tested and documented by industry and at Pacific Northwest National Laboratory, and are available in commercial RPMs built by several manufacturers. Moreover, energy windowing is being used in many deployed RPMs to reduce nuisance alarms and improve operational sensitivity during the screening of cargo. This paper describes energy windowing algorithms and demonstrates how these algorithms succeed when applied to 'controlled' experimental measurements and 'real world' vehicle traffic data
Additional details
Identifiers
- DOI
- 10.1016/j.nima.2006.01.053;
- PII
- S0168-9002(06)00105-7;
Publishing Information
- Journal Title
- Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
- Journal Volume
- 560
- Journal Issue
- 2
- Journal Page Range
- p. 373-387
- ISSN
- 0168-9002
- CODEN
- NIMAER
INIS
- Country of Publication
- Netherlands
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 37094186
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Descriptors DEI
- ALGORITHMS; CARGO; MANUFACTURERS; MONITORS; PLASTIC SCINTILLATORS; RADIATION DETECTION; RADIOACTIVE MATERIALS; SECURITY; SENSITIVITY; SHIELDING; VEHICLES
- Descriptors DEC
- DETECTION; MATERIALS; MATHEMATICAL LOGIC; MEASURING INSTRUMENTS; PHOSPHORS