Research on alarm triggered fault-diagnosis expert system for U-shaped tube breaking accident of steam generators
- 1. School of Mechatronic Engineering and Automation, Shanghai University, Shanghai (China)
- 2. School of Automatino Engineering, Shanghai University of Electric Power, Shanghai (China)
- 3. School of Energy and Mechanical Engineering, Shanghai University of Electric Power, Shanghai (China)
Description
According to the U-shaped tube breaking accident of steam generator (SGTR), this paper designs a fault-diagnosis expert system based on the alarm triggering. By analyzing the fault mechanism of SGTR accidents, the fault symptom is obtained. The parameters of the belief rule are set up based on the simulation experiment. The information fusion is conducted on the fault-diagnosis results from multiple expert systems to obtain the final diagnose result. The test result shows that the expert system can diagnose the SGTR accident accurately and rapidly, and provide with the operation guidance. (authors)
Additional details
Publishing Information
- Journal Title
- Nuclear Power Engineering
- Journal Volume
- 36
- Journal Issue
- 1
- Journal Page Range
- p. 98-103
- ISSN
- 0258-0926
INIS
- Country of Publication
- China
- Country of Input or Organization
- China
- INIS RN
- 48083734
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Descriptors DEI
- ACCIDENTS; ALARM SYSTEMS; DESIGN; EXPERT SYSTEMS; FAILURE MODE ANALYSIS; FAILURES; INFORMATION; OPERATION; SIMULATION; STEAM GENERATORS; SYMPTOMS; TUBES
- Descriptors DEC
- BOILERS; SYSTEM FAILURE ANALYSIS; SYSTEMS ANALYSIS; VAPOR GENERATORS
Optional Information
- Notes
- 5 figs., 4 tabs., 7 refs.