Published February 2015 | Version v1
Journal article

Research on alarm triggered fault-diagnosis expert system for U-shaped tube breaking accident of steam generators

  • 1. School of Mechatronic Engineering and Automation, Shanghai University, Shanghai (China)
  • 2. School of Automatino Engineering, Shanghai University of Electric Power, Shanghai (China)
  • 3. School of Energy and Mechanical Engineering, Shanghai University of Electric Power, Shanghai (China)

Description

According to the U-shaped tube breaking accident of steam generator (SGTR), this paper designs a fault-diagnosis expert system based on the alarm triggering. By analyzing the fault mechanism of SGTR accidents, the fault symptom is obtained. The parameters of the belief rule are set up based on the simulation experiment. The information fusion is conducted on the fault-diagnosis results from multiple expert systems to obtain the final diagnose result. The test result shows that the expert system can diagnose the SGTR accident accurately and rapidly, and provide with the operation guidance. (authors)

Additional details

Publishing Information

Journal Title
Nuclear Power Engineering
Journal Volume
36
Journal Issue
1
Journal Page Range
p. 98-103
ISSN
0258-0926

Optional Information

Notes
5 figs., 4 tabs., 7 refs.