Published October 1992 | Version v1
Report Restricted

Effect of flow leakage on the benchmarking of FLOWTRAN with Mark-22 mockup flow excursion test data from Babcock and Wilcox

Description

This report presents a revised analysis of the Babcock and Wilcox (B and W) downflow flow excursion tests that accounts for leakage between flow channels in the test assembly. Leak rates were estimated by comparing results from the downflow tests with those for upflow tests conducted using an identical assembly with some minor modifications. The upflow test assembly did not contain leaks. This revised analyses shows that FLOWTRAN with the SRS working criterion conservatively predicts onset of flow instability without using a local peaking factor to model heat transfer variations near the ribs

Availability note (English)

MF available from INIS under the Report Number.

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Publishing Information

Imprint Pagination
166 p.
Report number
WSRC-TR--92-422

Optional Information

Contract/Grant/Project number
Contract AC09-89SR18035
Notes
OSTI as DE93017274; NTIS; INIS; US Govt. Printing Office Dep.
Funding organization
USDOE, Washington, DC (United States).