Published 1986
| Version v1
Book
Qualification of CORECOOL using parametric spray heat transfer tests by various axial power distribution heated bundle
Description
Parametric spray heat transfer tests have been conducted under simulated spray cooling conditions of BWR during a LOCA using full scale electrically heated bundles with cosine, bottom and top peaked power distributions. The test parameters are spray flow rate, system pressure, bundle power and initial rod temperature. Using these test data, verification of mechanistic spray heat transfer evaluation code CORECOOL has been performed. It is verified that CORECOOL predicts well the maximum temperature transient in the rod bundle as well as average temperature transient under wide range of spray cooling conditions regardless of axial power distribution. (author)
Additional details
Publishing Information
- Publisher
- Atomic Energy Soc. of Japan.
- Imprint Place
- Tokyo (Japan)
- Imprint Title
- Proceedings of second international topical meeting on nuclear power plant thermal hydraulics and operations
- Imprint Pagination
- 1191 p.
- Journal Page Range
- p. 1/50-1/56.
Conference
- Title
- 2. international topical meeting on nuclear power plant thermal hydraulics and operations.
- Dates
- 15-17 Apr 1986.
- Place
- Tokyo (Japan).
INIS
- Country of Publication
- Japan
- Country of Input or Organization
- Japan
- INIS RN
- 18042199
- Subject category
- S22: GENERAL STUDIES OF NUCLEAR REACTORS;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- BWR TYPE REACTORS; C CODES; CORE SPRAY SYSTEMS; HEAT TRANSFER; LOSS OF COOLANT; REACTOR SAFETY EXPERIMENTS
- Descriptors DEC
- ACCIDENTS; COMPUTER CODES; ECCS; ENERGY TRANSFER; ENRICHED URANIUM REACTORS; POWER REACTORS; REACTOR ACCIDENTS; REACTOR PROTECTION SYSTEMS; REACTORS; THERMAL REACTORS; WATER COOLED REACTORS; WATER MODERATED REACTORS