Published January 2011 | Version v1
Book

Developments of quad channel pulse height analyzer for radon/thoron measurement

  • 1. Radiation Safety Systems Division, Bhabha Atomic Research Centre, Mumbai (India)
  • 2. Electronics Division, Bhabha Atomic Research Centre, Mumbai (India)
  • 3. Radiological Protection and Advisory Division, Bhabha Atomic Research Centre, Mumbai (India)

Description

Radon and thoron are naturally occurring noble radioactive gases, the exposure to which has a linear relationship to lung cancer risk. This paper describes development of an automated Radon/Thoron measurement system using an indigenously developed silicon PIN diode. This system employs the 8051 core architecture based Si-lab microcontroller (C-8051F340) integrated with LCD display, hex key pad, non volatile flash memory besides I/O ports interfaced with humidity-temperature sensors and air sampling pump. Air is sampled through a dehumidifier by using a software controlled dc pump. The positively charged progeny atoms are electro statically collected over the detector surface and the deposited radioactivity is assessed by alpha pulse height discrimination technique. The ionization charges produced due to the interaction of alpha particles in the charge depletion region of the diode which is reverse biased at 40V are collected and measured. The measurement circuit uses a charge sensitive preamplifier developed around a low noise opamp IC. The pulses are further processed through a spectroscopy amplifier to obtain distinct pulse height levels for four of the alpha emitting progenies of Rn and Tn namely 210Po, 214Po, 216Po and 212Po. These signals are input to the quad channel analyzer which provides four individual TTL pulses corresponding to four nuclides mentioned above. The analyzer outputs are processed by the microcontroller module to obtain the Rn/Tn concentration in Bq/M3. This portable system stores one week hourly individual channel data along with the corresponding Rn/Tn concentrations, temperature, humidity and can be transferred to pc. Preliminary studies have indicated that sensitivity as low as 0.50 cph/Bq.m-3 can be achieved by this system. (author)

Part of:
Proceedings of the symposium on advanced measurement techniques and instrumentation: abstract book

Additional details

Publishing Information

Publisher
Bhabha Atomic Research Centre
Imprint Place
Mumbai (India)
Imprint Title
Proceedings of the symposium on advanced measurement techniques and instrumentation: abstract book
Imprint Pagination
105 p.
Journal Page Range
p. 40

Conference

Title
symposium on advanced measurement techniques and instrumentation
Acronym
SAMTI-2011
Dates
2-4 Feb 2011
Place
Mumbai (India)

Optional Information

Notes
2 refs.