Published 1994 | Version v1
Miscellaneous

A Faraday cup array used in measurement of current distribution

  • 1. CAEP Inst. of Applied Electronics, Chengdu (China)

Description

Seventeen Faraday cups were fitted into a common housing to measure current distribution by 6 MeV, 100 kA electron beam from 'Flash-1' accelerator. Description of the instrument design and the electronic configurations are given along with the result at experiment of victual cathode oscillation exciting microwaves

Part of:
Proceedings of 7. national conference on nuclear electronics and nuclear detection technology: Pt.1

Additional details

Publishing Information

Imprint Title
Proceedings of 7. national conference on nuclear electronics and nuclear detection technology: Pt.1
Imprint Pagination
359 p.
Journal Page Range
p. 288-290.

Conference

Title
7. national conference on nuclear electronics and nuclear detection technology.
Dates
6-12 Oct 1994.
Place
Lushan (China).

INIS

Country of Publication
China
Country of Input or Organization
China
INIS RN
28018512
Subject category
S43: PARTICLE ACCELERATORS;
Resource subtype / Literary indicator
Conference, Non-conventional Literature
Descriptors DEI
ACCELERATORS; BEAM CURRENTS; CATHODES; CURRENT DENSITY; ELECTRON BEAMS; EXCURSIONS; FARADAY CUPS; LASERS; MEV RANGE 01-10; MICROWAVE RADIATION; OSCILLATIONS
Descriptors DEC
ACCIDENTS; AMPLIFIERS; BEAM MONITORS; BEAMS; CURRENTS; ELECTRODES; ELECTROMAGNETIC RADIATION; ENERGY RANGE; EQUIPMENT; LEPTON BEAMS; MEASURING INSTRUMENTS; MEV RANGE; MONITORS; PARTICLE BEAMS; RADIATIONS; REACTOR ACCIDENTS

Optional Information