Published April 1980 | Version v1
Journal article

Experimental value of percent variation in root-mean-square ex-core detector signal to the core barrel amplitude scale factor

  • 1. Combustion Engineering, Inc., Windsor, CT

Description

Ex-core neutron detector and core barrel-mounted accelerometer signals were used to determine the ratio of percent variation in the ex-core signal to core barrel amplitude. Based on these data, the nominal value, includig uncertainties, is 1.60 +- 0.24%/mm (0.0407 +- 0.006%/mil). This result is in agreement with both predictions, based on a one-dimensional transport model, and previously reported data

Additional details

Publishing Information

Journal Title
Nucl. Technol.
Journal Volume
48
Journal Issue
2
Series
Nucl. Technol.
Journal Page Range
122-127
ISSN