Published April 1980
| Version v1
Journal article
Experimental value of percent variation in root-mean-square ex-core detector signal to the core barrel amplitude scale factor
Description
Ex-core neutron detector and core barrel-mounted accelerometer signals were used to determine the ratio of percent variation in the ex-core signal to core barrel amplitude. Based on these data, the nominal value, includig uncertainties, is 1.60 +- 0.24%/mm (0.0407 +- 0.006%/mil). This result is in agreement with both predictions, based on a one-dimensional transport model, and previously reported data
Additional details
Publishing Information
- Journal Title
- Nucl. Technol.
- Journal Volume
- 48
- Journal Issue
- 2
- Series
- Nucl. Technol.
- Journal Page Range
- 122-127
- ISSN
- 0029-5450
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 12589025
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS; S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Descriptors DEI
- ACCELEROMETERS; MOTION DETECTION SYSTEMS; NEUTRON DETECTORS; PERFORMANCE; PWR TYPE REACTORS; REACTOR CORES
- Descriptors DEC
- MEASURING INSTRUMENTS; RADIATION DETECTORS; REACTOR COMPONENTS; REACTORS; WATER COOLED REACTORS; WATER MODERATED REACTORS