Published May 2019 | Version v1
Journal article

A CsI(Tl) detector array for the measurement of light charged particles in heavy-ion reactions

  • 1. Homi Bhabha National Institute, Anushaktinagar, Mumbai 400 094 (India)
  • 2. Nuclear Physics Division, Bhabha Atomic Research Centre, Mumbai 400085 (India)
  • 3. INO Cell, Tata Institute of Fundamental Research, Mumbai 400005 (India)
  • 4. Department of Nuclear and Atomic Physics, Tata Institute of Fundamental Research, Mumbai 400005 (India)

Description

An array of eight CsI(Tl) detectors has been set up to measure the light charged particles in nuclear reactions using heavy ions from the Pelletron Linac Facility, Mumbai. The energy response of CsI(Tl) detector to α-particles from 5 to 40 MeV is measured using radioactive sources and the 12C(12C, α) reaction populating discrete states in 20Ne. The energy non-linearity and the count rate effect on the pulse shape discrimination property have also been measured and observed the deterioration of pulse shape discrimination with higher count rate.

Availability note (English)

Available from http://dx.doi.org/10.1016/j.nima.2019.01.098

Additional details

Identifiers

DOI
10.1016/j.nima.2019.01.098;
PII
S0168900219301706;

Publishing Information

Journal Title
Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
Journal Volume
925
Journal Page Range
p. 184-187
ISSN
0168-9002
CODEN
NIMAER

Optional Information

Copyright
Copyright (c) 2019 Elsevier B.V. All rights reserved.