Published April 2006 | Version v1
Journal article

3D conformal HDR-brachy- and external beam therapy plus simultaneous Cisplatin for high-risk cervical cancer: Clinical experience with 3 year follow-up

  • 1. Department of Radiotherapy and Radiobiology, Medical University of Vienna, Vienna (Austria)
  • 2. Division of Clinical Oncology, Department of Internal Medicine I and Department of Gynecology and Obstetrics, Medical University of Vienna, Vienna (Austria)
  • 3. Department of Gynecology and Obstetrics, Medical University of Vienna, Vienna (Austria)
  • 4. Department of Radiotherapy, Hospital of Lainz, Vienna (Austria)

Description

Background and purpose: To assess feasibility, safety and effectiveness of CT-based 3D conformal external beam radiotherapy (EBRT) plus concurrent cisplatin and MRI-based 3D conformal HDR-brachytherapy (HDR-BT) in the treatment of advanced cervical cancer. Patients and methods: A total of 48 patients with advanced cervical cancer, treated with CT-based EBRT plus simultaneous cisplatin chemotherapy (40 mg/m2 of body surface per week for 5 weeks) and MRI-based HDR-BT, were included for analysis. Results: All patients completed radiotherapy as planned and 90% received at least four cycles chemotherapy. Frequencies of CTC grade 3 anaemia, grade 3-4 leucopenia and grade 3 thrombocytopenia were 4, 23 and 10%, respectively. Two patients developed deep vein thrombosis and one non-fatal pulmonary embolism. Grade 4 genitourinary late side effects (bladder) occurred in 2 patients. No grade 3-4 gastrointestinal side effects were observed. Complete response (CR) was obtained in 45 patients (94%). After a median follow-up of 33 months, 27 patients were disease free. Actuarial overall survival at 3 years was 61%, progression free survival 51% and continuous complete remission for true pelvis 85%. Conclusions: MRI-based 3D HDR-BT and 3D EBRT plus cisplatin appears to be safe and effective, although acute haematological toxicity is increased. Gastrointestinal morbidity is minimal when prospectively applying 3D dose volume constraints and MRI-based 3D dose volume adaptation

Additional details

Identifiers

DOI
10.1016/j.radonc.2006.01.007;
PII
S0167-8140(06)00028-4;

Publishing Information

Journal Title
Radiotherapy and Oncology
Journal Volume
79
Journal Issue
1
Journal Page Range
p. 80-86
ISSN
0167-8140
CODEN
RAONDT

Optional Information

Copyright
Copyright (c) 2006 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.