Published January 2000 | Version v1
Journal article

Evaluation on radiation features of the KUR deuterium neutron irradiation equipment. Neutron energy spectra and neutron- and gamma-ray absorption dose rate

  • 1. Kyoto Univ., Kumatori, Osaka (Japan). Research Reactor Inst.

Description

The deuterium irradiation equipment at reactor for research in Kyoto University (KUR) was reformed at main aim of upgrading of neutron capture therapy (NCT) from November, 1995 to March, 1996. Neutron energy spectra at reference radiation position evaluated on a partial radiation mode by multiple activated foil method, was introduced. As a result of carrying out a simulation calculation using two dimensional transmission calculation supposing medical radiation using the obtained spectra, experimental results could be followed satisfactorily in total. And, comparison with differential absorption dose rate measured by using twin-type ionization box and semiconductor detector for medical probe was also carried out. (G.K.)

Additional details

Publishing Information

Journal Title
Kyoto Daigaku Genshiro Jikkensho Gakujutsu Koenkai Hobunshu
Journal Volume
34
Journal Page Range
p. 154-159
ISSN
0917-1746

Conference

Title
34. scientific meeting of the Research Reactor Institute, Kyoto University
Dates
25-27 Jan 2000
Place
Kumatori, Osaka (Japan)