A method for evaluating the transmission properties of ultracold-neutron guides

  • 1. Physik-Department, Technische Universitaet Muenchen, Garching D-85748 (Germany) and PNPI RAS, Gatchina, Leningrad district 188300, Russia (Russian Federation)
  • 2. Physik-Department, Technische Universitaet Muenchen, Garching D-85748 (Germany)
  • 3. Institut Laue-Langevin, 38042 Grenoble (France)

Description

A method for evaluating the properties of guides for ultracold neutrons (UCN) has been developed as an extension of the common technique for measuring UCN losses in the sample contained between two diaphragms. With two measurements at both ends of the guide one can evaluate both, the loss probability μ per wall collision and the probability f for diffuse scattering from the wall. A 3.4m long aluminum tube coated with a double layer of stainless steel (thickness 500nm) and beryllium (thickness 250nm), proposed as a UCN guide for the Mini-D2 UCN source at the FRM-II reactor at Garching, was tested. We obtained μ=(1.1+/-0.1)x10-3 and f=0.18+/-0.04. Systematic errors and a possible improvement of the method are discussed

Additional details

Identifiers

DOI
10.1016/j.nima.2006.09.104;
PII
S0168-9002(06)01765-7;

Publishing Information

Journal Title
Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
Journal Volume
570
Journal Issue
1
Journal Page Range
p. 101-106