Published June 2015 | Version v1
Journal article

Collimator design for fuel areal density diagnosis via down-scattered neutrons measurement on SG-Ⅲ facility

  • 1. Institute of Nuclear Physics and Chemistry, CAEP, Mianyang (China)

Description

In the inertial confinement fusion (ICF) experiment, down-scattered neutrons for fuel areal density measurement need to be separated from other background. The background on Shenguang Ⅲ facility is analyzed in detail by Monte Carlo for the DD fuel. As a result, the background is mostly from the process that primary neutrons scatter through vacuum chamber, surrounding diagnostic platforms, ceiling and floor. According to the analysis, appropriate materials and shielding solution are chosen. And the structure of the collimator is optimized by Monte Carlo. The design meets the experimental requirements. (authors)

Additional details

Identifiers

Publishing Information

Journal Title
High Power Laser and Particle Beams
Journal Volume
27
Journal Issue
6
Journal Page Range
[5 p.]
ISSN
1001-4322

Optional Information

Notes
12 figs., 10 refs.; http://dx.doi.org/10.11884/HPLPB201527.062005