Published February 2012 | Version v1
Journal article

Design of environment monitoring system to evaluate radionuclide release from subsystem on PWR nuclear power accident

  • 1. Pusat Teknologi Reaktor dan Keselamatan Nuklir – BATAN, Serpong (Indonesia)

Description

Nuclear Power Plan (NPP) as a renewable energy source is selected as an alternative, because it has many advantages that is environmentally friendly, fuel supply which is independent of the season, and the price that can compete with other power plants. However, the existence of some public skepticism about nuclear radiation safety, the government must be convinced about the operation of nuclear power plants are safe and secure. Research on the design of environment monitoring system for evaluation of radionuclide release from the reactor subsystems and the environment due to accidents at power reactors has been done. The study was conducted by calculating the distribution of radionuclide release into the reactor subsystem and the environment and also to build the environment radiation monitoring system. Environmental monitoring system consists of a radiation counter, early warning systems, meteorological measurement systems, GPS systems and GIS. Radiation monitoring system used to record the data of radiation, meteorological measurement system used to record data of wind and speed direction, while the GPS system is used to determine position of data measurements. The data is then transmitted to a data acquisition system and then to be transmitted to the control center. Collection and transmission of data is done via SMS formatting using a modem device that is placed in the control center. The control center receives measurement data from various places. In this case the control center has a function as an SMS Gateway. This system can visualize for different measurement locations. Furthermore, radiation data and position data to be integrated with digital maps. System integration is then visualized in a personal computer. To position of measurements directly visualized on the map and also look for the data displayed on a monitor as a red or green circle colour. That colour indicated as a safe limit of radiation monitor. When the cycle colour is red, the system will turn on alarm in the control room and then can be take action in accordance with existing nuclear emergency procedures as shown in PSAR. (author)

Additional details

Additional titles

Original title (Indonesian)
Desain sistem pemantau lingkungan untuk evaluasi lepasan radionuklida dari subsistem pada kecelakaan reaktor daya PWR

Publishing Information

Journal Title
Jurnal Teknologi Reaktor Nuklir
Journal Volume
14
Journal Issue
1
Journal Page Range
p. 54-64
ISSN
1411-240X

Optional Information

Notes
10 refs., 14 figs.