Published August 1996 | Version v1
Journal article

Production of 95mTc tracer for 99Tc analysis by ICP-MS

  • 1. Kyushu Univ., Fukuoka (Japan). Faculty of Science

Description

Analysis of 99Tc in the environment have been interested because of a long term radioecological effect of 99Tc due to its long half-life. One of the problems on 99Tc analysis is a tracer since there is no stable isotopes in Tc. Development of 99Tc determination by ICP-MS enables us to use 95mTc as a yield monitor. The radiochemical yield is evaluated by gamma spectrometry of 95mTc and 99Tc is determined by mass spectrometry without any interference by 95mTc tracer added to the sample. We produced 95mTc without 99Tc by an irradiation of metal Nb with 40 MeV alpha particles using cyclotron. The 0.1 mm thickness Nb foil stacked 4 pieces was irradiated for 21 h at beam current of 1.5 μC, dissolved in a mixture of HNO3 and HF, and 95mTc was isolated and purified chemically. No contamination of 99Tc was confirmed on 95mTc fraction. (author)

Additional details

Publishing Information

Journal Title
Radioisotopes (Tokyo)
Journal Volume
45
Journal Issue
8
Journal Page Range
p. 511-514.
ISSN
0033-8303
CODEN
RAISAB