Published September 1, 2019 | Version v1
Journal article

Direct ion content measurements in a non-sputtering magnetron discharge

  • 1. National Research Nuclear University MEPhI (Moscow Engineering Physics Institute), 31 Kashirskoye Shosse, Moscow 115409 (Russian Federation)

Description

In present contribution we report the first direct measurements of ion fluxes in a non-sputtering magnetron discharge (NSMD) with Al cathode in Ar/O2 mixtures. The diagnostic unit comprising three-electrode electrostatic lens ion extractor, magnetic sector mass-analyzer, and a vacuum electron multiplier was calibrated and then used to record the time-resolved ion counts of Al+ and Ar+ both in NSMD and arc regimes. The results clearly indicate that in NSMD the dominant species are Ar ions while Al ion signal is lower than the sensitivity limit due to noise level, in contrast to the arc discharge. The capabilities of the diagnostics setup and its sensitivity limits are discussed.

Availability note (English)

Available from http://dx.doi.org/10.1088/1748-0221/14/09/C09004

Additional details

Publishing Information

Journal Title
Journal of Instrumentation
Journal Volume
14
Journal Issue
09
Journal Page Range
p. C09004
ISSN
1748-0221