Published May 2008 | Version v1
Journal article

Analysis of IAEA environmental samples for plutonium and uranium by ICP/MS in support of international safeguards

  • 1. Pacific Northwest National Laboratory (PNNL), Richland, WA (United States)

Description

A method for the separation and determination of total and isotopic uranium and plutonium by ICP/MS was developed for IAEA samples on cellulose-based media. Preparation of the IAEA samples involved a series of redox chemistries and separations using TRUR resin (Eichrom). The sample introduction system, an APEX nebulizer (Elemental Scientific, Inc.), provided enhanced nebulization for a several-fold increase in sensitivity and reduction in background. Application of mass bias (ALPHA) correction factors greatly improved the precision of the data. By combining the enhancements of chemical separation, instrumentation and data processing, detection levels for uranium and plutonium approached high attogram levels. (author)

Additional details

Publishing Information

Journal Title
Journal of Radioanalytical and Nuclear Chemistry
Journal Volume
276
Journal Issue
2
Journal Page Range
p. 489-492
ISSN
0236-5731
CODEN
JRNCDM

Optional Information

Notes
6 refs.