Published March 2015 | Version v1
Journal article

Standardized perfusion value of the esophageal carcinoma and its correlation with quantitative CT perfusion parameter values

  • 1. Unit of Digestive Radiology (First University Surgical Clinic), Center of Radiology and MR, Clinical Center of Serbia, Belgrade (Serbia)
  • 2. Faculty of Medicine, University of Belgrade, Belgrade (Serbia)
  • 3. Center of Nuclear Medicine, Clinical Center of Serbia, Belgrade (Serbia)

Description

Purpose: Standardized perfusion value (SPV) is a universal indicator of tissue perfusion, normalized to the whole-body perfusion, which was proposed to simplify, unify and allow the interchangeability among the perfusion measurements and comparison between the tumor perfusion and metabolism. The aims of our study were to assess the standardized perfusion value (SPV) of the esophageal carcinoma, and its correlation with quantitative CT perfusion measurements: blood flow (BF), blood volume (BV), mean transit time (MTT) and permeability surface area product (PS) of the same tumor volume samples, which were obtained by deconvolution-based CT perfusion analysis. Methods: Forty CT perfusion studies of the esophageal cancer were analyzed, using the commercial deconvolution-based CT perfusion software (Perfusion 3.0, GE Healthcare). The SPV of the esophageal tumor and neighboring skeletal muscle were correlated with the corresponding mean tumor and muscle quantitative CT perfusion parameter values, using Spearman's rank correlation coefficient (rS). Results: Median SPV of the esophageal carcinoma (7.1; range: 2.8–13.4) significantly differed from the SPV of the skeletal muscle (median: 1.0; range: 0.4–2.4), (Z = −5.511, p < 0.001). The cut-off value of the SPV of 2.5 enabled discrimination of esophageal cancer from the skeletal muscle with sensitivity and specificity of 100%. SPV of the esophageal carcinoma significantly correlated with corresponding tumor BF (rS = 0.484, p = 0.002), BV (rS = 0.637, p < 0.001) and PS (rS = 0.432, p = 0.005), and SPV of the skeletal muscle significantly correlated with corresponding muscle BF (rS = 0.573, p < 0.001), BV (rS = 0.849, p < 0.001) and PS (rS = 0.761, p < 0.001). Conclusions: We presented a database of the SPV for the esophageal cancer and proved that SPV of the esophageal neoplasm significantly differs from the SPV of the skeletal muscle, which represented a sample of healthy tissue. The SPV was validated against quantitative CT perfusion measurements and statistically significant correlation was proved

Availability note (English)

Available from http://dx.doi.org/10.1016/j.ejrad.2014.12.004

Additional details

Identifiers

DOI
10.1016/j.ejrad.2014.12.004;
PII
S0720-048X(14)00570-1;

Publishing Information

Journal Title
European Journal of Radiology
Journal Volume
84
Journal Issue
3
Journal Page Range
p. 350-359
ISSN
0720-048X
CODEN
EJRADR

Optional Information

Copyright
Copyright (c) 2015 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.