Published January 2013
| Version v1
Journal article
Design of a pre-collimator system for neutronics benchmark experiment
- 1. Science and Technology on Nuclear Data Laboratory, China Institute of Atomic Energy, Beijing (China)
- 2. University of South China, Hengyang (China)
Description
Benchmark experiment is an important means to inspect the reliability and accuracy of the evaluated nuclear data, the effect/background ratios are the important parameters to weight the quality of experimental data. In order to obtain higher effect/background ratios, a pre-collimator system was designed for benchmark experiment. This system mainly consists of a pre-collimator and a shadow cone, The MCNP-4C code was used to simulate the background spectra under various conditions, from the results we found that with the pre-collimator system have a very marked improvement in the effect/background ratios. (authors)
Additional details
Publishing Information
- Journal Title
- Nuclear Techniques
- Journal Volume
- 36
- Journal Issue
- 1
- Journal Page Range
- [6 p.]
- ISSN
- 0253-3219
INIS
- Country of Publication
- China
- Country of Input or Organization
- China
- INIS RN
- 47057307
- Subject category
- S70: PLASMA PHYSICS AND FUSION TECHNOLOGY;
- Descriptors DEI
- ACCURACY; BENCHMARKS; COLLIMATORS; CONES; DESIGN; NEUTRONS; RELIABILITY; SPECTRA; WEIGHT
- Descriptors DEC
- BARYONS; ELEMENTARY PARTICLES; FERMIONS; HADRONS; NUCLEONS
Optional Information
- Notes
- 9 figs., 7 refs., 010201-1-010201-6